Register Interest: (Enter Valid Email Address and hit Return)
Description: The EXHEAT® ‘FAW’ range of air warmers has been designed for heating small work or storage areas and similar applications, located in Zone 1 or 2 Hazardous Areas, where the flammable atmosphere is a group IIA, IIB or IIC Gas.
Lightweight enclosure certified weatherproof to IP66/67.
Suitable for single or three phase (3 or 4 wire) a.c. and d.c. power supplies.
Temperature classification T2, T3 and T4 available.
Suitable for floor or wall mounting (additional brackets may be required).
1 off 20mm cable entry is provided as standard, additional entries can be provided if required.
Coated Mild Steel or Stainless Steel.
Optional range of flameproof room thermostats can also be provided.
Suitable for ambient temperatures from -60°C to +60°C
Individually replaceable heating elements.
Typical Application
Aircraft Hangers
Fuel servicing areas
Chemical Plants
Offshore installations
Battery Stores
Gas Installations
‘FAW’ Hazardous Area Air Warmer Technical Data Tables:
Click the Title to toggle the display status of the tables, Click the product row to view full information regarding the size/specification or to add an item to your basket.
Product Type: FAW Element Sheath Material: Stainless Steel Enclosure Material: Mild Steel Enclosure Finish: Powder coated grey (hammered) Enclosure Protection: IP66 Temperature Control: Limited by permitted ambient Supply: See Table ATEX Category: Ex II 2 G Ex Marking Code: Ex e II Temperature Class: T3
Product Type: FAW-C Element Sheath Material: Stainless Steel Enclosure Material: Stainless Steel Enclosure Finish: Natural Enclosure Protection: IP66 Temperature Control: Limited by permitted ambient Supply: See Table ATEX Category: Ex II 2 G Ex Marking Code: Ex e II Temperature Class: T3
Product Type: FAW Element Sheath Material: Stainless Steel Enclosure Material: Mild Steel Enclosure Finish: Powder coated grey (hammered) Enclosure Protection: IP66 Temperature Control: Limited by permitted ambient Supply: See Table ATEX Category: Ex II 2 G Ex Marking Code: Ex e II Temperature Class: T4
Product Type: FAW Element Sheath Material: Stainless Steel Enclosure Material: Mild Steel Enclosure Finish: Powder coated grey (hammered) Enclosure Protection: IP66 Temperature Control: Limited by permitted ambient Supply: See Table ATEX Category: Ex II 2 G Ex Marking Code: Ex e II Temperature Class: T2
Product Type: FAW Enclosure Material: Stainless Steel Enclosure Finish: Natural Temperature Control: Limited by permitted ambient Supply: See Table ATEX Category: Ex II 2 G Ex Marking Code: Ex e II Temperature Class: T3
Product Type: FAW Enclosure Material: Stainless Steel Enclosure Finish: Natural Temperature Control: Limited by permitted ambient Supply: See Table ATEX Category: Ex II 2 G Ex Marking Code: Ex e II Temperature Class: T4
Product Type: FAW Enclosure Material: Stainless Steel Enclosure Finish: Natural Temperature Control: Limited by permitted ambient Supply: See Table ATEX Category: Ex II 2 G Ex Marking Code: Ex e II Temperature Class: T2
Product Type: FCR Enclosure Material: Mild Steel Enclosure Finish: Painted grey (RAL 7032) Enclosure Protection: IP66 Temperature Control: Limited by permitted ambient Supply: See Table ATEX Category: Ex II 2 G Ex Marking Code: Ex e II Temperature Class: T3