FP Hazardous Area Immersion Heaters
Product Applications | ||
---|---|---|
|
|
|
|
|
|
|
|
|
|
|
The FP electric heater comprises a large range of process immersion heaters, certified for use in hazardous areas and are custom built to meet client specifications.
Features
- Certified to ATEX or IECEx standards
- Terminal box is certified weatherproof to IP66 as well as Type 4 or 4X standards
- Temperature classifications T1 to T6
- Up to 1400kW
- Elements are specially sealed to prevent moisture ingress
- Elements are individually replaceable on site without the need for special tools
- Withdrawable type elements are available to facilitate replacement without draining the vessel
- Suitable and certified for use in high ambient temperatures (e.g. Middle East)
- Anti-condensation heaters fitted, if required
Specifications
Certifications | ATEX / IECEx II 2 G/D Ex d IIC T1 to T6 Gb Ex tb IIIC T85 to T450°C Db IP66 EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-31 CSA (CEC / NEC) Class I, Div 1, Groups A, B, C, D; T1 to T6, Enclosure Type 4 or 4X CSA (CEC) Ex d IIC; T1 to T6 Gb, IP66 (CAN) CSA (NEC) Class I, Zone 1, AEx d IIC; T1 to T6 Gb, IP66 (USA) CU TR (EAC), CNEx, CCOE, Inmetro, KGS |
---|---|
Terminal Box | Manufactured from low temperature carbon steel or stainless steel throughout, with screwed-on lid to suit the hazardous environment |
Elements | Manufactured from 80/20 NiCr resistance wire with high purity compacted magnesium oxide powder sheathed within corrosion / erosion resistant tube, eg: Incoloy 800/825 316/316L stainless steel Inconel 600/625 321 stainless steel Titanium Monel |
Internals | Elements are supported in a baffle type support assembly to prevent vibration and element deformation |
Voltage | Suitable for voltages up to 690V (600V CAN and USA) |