Percentage Rated Wattage for Various Applied Voltages

Heating elements are frequently used at voltages other than those shown in our catalogue. The percentages in this table are used to determine the resulting wattage *.

Applied Voltage Rated Voltage
110 115 120 208 220 230 240 277 380 415 440 460 480 550
110 100% 91% 84% 28% 25% 23% 21% 16% 8.4% 7.0% 6.2% 5.7% 5.2% 4.0%
115 100% 92% 31% 27% 25% 23% 17% 9.0% 7.6% 6.7% 6.2% 5.7% 4.3%
120 100% 33% 30% 27% 25% 19% 10% 8.4% 7.4% 6.8% 6.3% 4.8%
208 100% 89% 82% 75% 56% 30% 25% 22% 20% 19% 14%
220 100% 91% 84% 63% 34% 28% 25% 23% 21% 16%
230 100% 92% 69% 37% 31% 27% 25% 23% 17%
240 100% 75% 40% 33% 30% 27% 25% 19%
277 100% 53% 45% 40% 36% 33% 25%
380 100% 84% 75% 68% 63% 47%
415 100% 89% 81% 75% 57%
440 100% 91% 84% 64%
460 100% 92% 70%
480 100% 76%
550 100%